Near-infrared holography extends lensless microscopy into thick scattering tissue
Researchers at Warsaw University of Technology say near-infrared light and a larger sample-sensor gap let lensless holographic microscopy recover detail through tissue-like scattering layers far beyond its visible-light limit. The advance could improve fast, wide-field imaging of thick biological samples without lenses, labels, or scanning.
Why it matters: - Lensless holographic microscopy has been limited by strong scattering in thick specimens, which usually destroys the reference wave needed for reconstruction. - The new results show that near-infrared light can preserve usable information through much thicker tissue-like media than visible light, expanding a method that is compact and wide-field by design. - The work also suggests that sample-sensor spacing, once treated as a constraint, can become a tuning parameter for better resolution in complex media.
What happened: - Researchers at Warsaw University of Technology pushed in-line lensless holographic microscopy into the multiple-scattering regime. - The team tested six illumination wavelengths from 480 to 1100 nm on a standard silicon sensor without changing the core imaging platform. - The study was led by Prof. Maciej Trusiak's group at the Quantitative Computational Imaging Lab, Institute of Micromechanics and Photonics, Warsaw University of Technology, and was published online in Opto-Electronic Advances on September 20, 2026. - The original paper is titled Near-infrared lensless holographic microscopy on a standard sensor for label-free mesoscale imaging in multiple scattering.
The details: - Tissue-mimicking milk layers provided controlled scattering conditions. - Calibrated targets were used to measure the finest resolvable features. - Visible-light operation became fully unresolved at scattering-layer thicknesses of 180 to 360 µm, depending on wavelength. - At 1100 nm, resolvable features survived through about 1.4 mm of tissue-like medium. - That depth was nearly four times greater than what the system reached at 632 nm. - The CMOS sensor's quantum efficiency at 1100 nm was just 0.19%, yet reconstructions remained robust. - Increasing the sample-sensor distance from about 3 mm to 12 mm improved lateral resolution from roughly 11 µm to 5.5 µm. - The team used the full sensor area as the field of view, about 116 mm2, without raster scanning or image stitching. - The system produced label-free amplitude and phase images of uncleared mouse liver sections up to 60 µm and brain sections up to 250 µm.
Between the lines: - The result challenges the assumption that lensless holography must stay close to the sensor and confined to weakly scattering samples. - Near-infrared illumination appears to leave more recoverable structure in turbid specimens, even when the detector is not optimized for that wavelength. - The distance effect suggests that propagation can help separate useful fringes from diffuse background under strong scattering. - This is still an in vitro imaging advance, not a claim of deep in-body imaging.
What's next: - Prof. Trusiak said future work could combine distance-aware acquisition with scattering-aware or physics-informed reconstruction and more sensitive detectors. - The team pointed to faster tissue survey, computational imaging through complex media, and compact lab instruments as likely next steps. - The collaboration model may help move the method from resolution tests to biologically meaningful tissue architecture in broader sample types.
The bottom line: - Near-infrared lensless holography on a standard sensor extends a traditionally visible-light method into much thicker scattering samples and opens a new route to fast, wide-field, label-free tissue imaging.
Disclaimer: This article was produced by AGP Wire with the assistance of artificial intelligence based on original source content and has been refined to improve clarity, structure, and readability. This content is provided on an “as is” basis. While care has been taken in its preparation, it may contain inaccuracies or omissions, and readers should consult the original source and independently verify key information where appropriate. This content is for informational purposes only and does not constitute legal, financial, investment, or other professional advice.
Sign up for:
Central Europe
The daily local news briefing you can trust. Every day. Subscribe now.
Check Your Email!
We sent a one-time activation link to: .
Confirm it's you by clicking the email link.
If the email is not in your inbox, check spam or try again.
Welcome back!
is already signed up. Check your inbox for updates.